Hip joint simulators were developed for predicting, bu attempting to duplicate in vitro physiological loads and motion, the wear rate that total hip replacements are likely to show in vivo. From a theoretical point of view, loading and motion cycles of hip joints could be closely reproduced by three rotation actuators and three force actuators. However existing devices have been designed assuming that some of these degrees of freedom are negligible, in order to reduce the complexity of the equipment. The present study singles out some preliminary indication on the design choices regarding the spatial configuration of loading and motion actuators. The aim is to define theoretically a simplified simulator but still to apply the most physiologically realistic loading cycle to the specimen. Copyright

Discussion on the design of a hip joint simulator / M., Viceconti; G., Cavallotti; Andrisano, Angelo Oreste; A., Toni. - In: MEDICAL ENGINEERING & PHYSICS. - ISSN 1350-4533. - ELETTRONICO. - 18:(1996), pp. 234-240.

Discussion on the design of a hip joint simulator

ANDRISANO, Angelo Oreste;
1996

Abstract

Hip joint simulators were developed for predicting, bu attempting to duplicate in vitro physiological loads and motion, the wear rate that total hip replacements are likely to show in vivo. From a theoretical point of view, loading and motion cycles of hip joints could be closely reproduced by three rotation actuators and three force actuators. However existing devices have been designed assuming that some of these degrees of freedom are negligible, in order to reduce the complexity of the equipment. The present study singles out some preliminary indication on the design choices regarding the spatial configuration of loading and motion actuators. The aim is to define theoretically a simplified simulator but still to apply the most physiologically realistic loading cycle to the specimen. Copyright
1996
18
234
240
Discussion on the design of a hip joint simulator / M., Viceconti; G., Cavallotti; Andrisano, Angelo Oreste; A., Toni. - In: MEDICAL ENGINEERING & PHYSICS. - ISSN 1350-4533. - ELETTRONICO. - 18:(1996), pp. 234-240.
M., Viceconti; G., Cavallotti; Andrisano, Angelo Oreste; A., Toni
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

Licenza Creative Commons
I metadati presenti in IRIS UNIMORE sono rilasciati con licenza Creative Commons CC0 1.0 Universal, mentre i file delle pubblicazioni sono rilasciati con licenza Attribuzione 4.0 Internazionale (CC BY 4.0), salvo diversa indicazione.
In caso di violazione di copyright, contattare Supporto Iris

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11380/306073
Citazioni
  • ???jsp.display-item.citation.pmc??? 1
  • Scopus 20
  • ???jsp.display-item.citation.isi??? 21
social impact