Conventional-size electrodes and microelectrodes coated by electrogenerated poly[4,4'-bis(butylsulfanyl)-2,2'-bithiophene] have been tested with respect to the electrocatalytic oxidation of a particularly interesting analyte, i.e., ascorbic acid, in different concentrations of phosphate buffer, aqueous solution. Linear sweep and cyclic voltammetry have been used and the quantities related to the analyte concentration were the peak current and the diffusion (t(-1/2)) deconvoluted peak current in the case of conventional-size and of microelectrode, respectively. Fairly good linear correlation could be found; a particularly wide linearity range was obtained by working with the microelectrode. It showed to give good results also at a very low (10(-4) M) phosphate buffer-supporting electrolyte concentration. The actual interference on the analysis of compounds often coupled with ascorbic acid in natural or pharmaceutical products has been studied.

Polythiophene derivative conducting polymer modified electrodes and microelectrodes for determination of ascorbic acid. Effect of possible interferents / S., Lupu; Mucci, Adele; Pigani, Laura; Seeber, Renato; Zanardi, Chiara. - In: ELECTROANALYSIS. - ISSN 1040-0397. - STAMPA. - 14:7-8(2002), pp. 519-525. [10.1002/1521-4109(200204)14:7/8<519::AID-ELAN519>3.0.CO;2-G]

Polythiophene derivative conducting polymer modified electrodes and microelectrodes for determination of ascorbic acid. Effect of possible interferents

MUCCI, Adele;PIGANI, Laura;SEEBER, Renato;ZANARDI, Chiara
2002

Abstract

Conventional-size electrodes and microelectrodes coated by electrogenerated poly[4,4'-bis(butylsulfanyl)-2,2'-bithiophene] have been tested with respect to the electrocatalytic oxidation of a particularly interesting analyte, i.e., ascorbic acid, in different concentrations of phosphate buffer, aqueous solution. Linear sweep and cyclic voltammetry have been used and the quantities related to the analyte concentration were the peak current and the diffusion (t(-1/2)) deconvoluted peak current in the case of conventional-size and of microelectrode, respectively. Fairly good linear correlation could be found; a particularly wide linearity range was obtained by working with the microelectrode. It showed to give good results also at a very low (10(-4) M) phosphate buffer-supporting electrolyte concentration. The actual interference on the analysis of compounds often coupled with ascorbic acid in natural or pharmaceutical products has been studied.
2002
14
7-8
519
525
Polythiophene derivative conducting polymer modified electrodes and microelectrodes for determination of ascorbic acid. Effect of possible interferents / S., Lupu; Mucci, Adele; Pigani, Laura; Seeber, Renato; Zanardi, Chiara. - In: ELECTROANALYSIS. - ISSN 1040-0397. - STAMPA. - 14:7-8(2002), pp. 519-525. [10.1002/1521-4109(200204)14:7/8<519::AID-ELAN519>3.0.CO;2-G]
S., Lupu; Mucci, Adele; Pigani, Laura; Seeber, Renato; Zanardi, Chiara
File in questo prodotto:
File Dimensione Formato  
Lupu_et_al-2002-Electroanalysis.pdf

Accesso riservato

Tipologia: Versione pubblicata dall'editore
Dimensione 740.38 kB
Formato Adobe PDF
740.38 kB Adobe PDF   Visualizza/Apri   Richiedi una copia
Pubblicazioni consigliate

Licenza Creative Commons
I metadati presenti in IRIS UNIMORE sono rilasciati con licenza Creative Commons CC0 1.0 Universal, mentre i file delle pubblicazioni sono rilasciati con licenza Attribuzione 4.0 Internazionale (CC BY 4.0), salvo diversa indicazione.
In caso di violazione di copyright, contattare Supporto Iris

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11380/305526
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 59
  • ???jsp.display-item.citation.isi??? 61
social impact