Background: guidelines for optimized use of digital follow-up of melanocytic lesions are not yet available, and little is known about inclusion criteria adopted in clinical practice. Objective. Our purpose was to describe the frequency of digital follow-up adoption in melanoma screening, the characteristics of patients and lesions selected, and the predictors of duration of the intervals of digital follow-up. Methods: Baseline characteristics of patients and lesions selected for digital follow-up in 12 Italian pigmented lesion clinics were examined. Predictors of a short follow-up interval (<= 3 months) compared with a 6-month interval were investigated by means of logistic regression analysis. Results: Out of 2116 subjects consecutively examined, 409 were submitted to digital follow-up (19.3%), with 1.6 mean lesions found per patient (range, 1-9; median, 1). According to an a posteriori analysis, 15.2% of the lesions were diagnostically equivocal and 7.8% of lesions had a total dermoscopy score (TDS) suggestive of malignancy. However, large differences in the TDS were found among the participating centers. Determinants of a short follow-up interval, adopted in 40.8% of patients, were the personal history of melanoma (odds ratio [OR] 2.56, 95% confidence interval [CI] 1.09-5.99) and the presence of atypical nevi (at least one atypical nevus (OR 4.54, 95% CI 2.45-8.42). Unexpectedly, the dermoscopic atypia of the lesion (TDS >4.75) was associated only with a marginal effect on the scheduled duration of follow-up interval (OR 1.34, 95% CI 0.97-1.86). These findings were confirmed by a multivariate analysis. Limitations. The adoption of different digital dermoscopy systems in the participating centers may have limited the reliability of the TDS assigned by a central group to dermoscopy images. Conclusions. Practicing dermatologists who use digital epiluminescence microscopy in screening for melanoma decided to submit at least one melanocytic lesion to digital follow-up for approximately I patient for every 5 examined. This implies costs and time spent that need to be evaluated together with the benefits of this procedure from a large-scale perspective. The lack of well-defined guidelines for inclusion and exclusion criteria may hamper optimized use of digital follow-up in daily practice.

Baseline factors influencing decisions on digital follow-up of melanocytic lesions in daily practice: An Italian multicenter survey / P., Carli; G., Ghigliotti; M., Gnone; A., Chiarugi; E., Crocetti; S., Astorino; Ua, Berti; P., Broganelli; A., Carcaterra; Mt, Corradin; Pellacani, Giovanni; D., Piccolo; M., Risulo; I., Stanganelli; V., De Giorgi. - In: JOURNAL OF THE AMERICAN ACADEMY OF DERMATOLOGY. - ISSN 0190-9622. - STAMPA. - 55:2(2006), pp. 256-262. [10.1016/j.jaad.2005.12.026]

Baseline factors influencing decisions on digital follow-up of melanocytic lesions in daily practice: An Italian multicenter survey

PELLACANI, Giovanni;
2006

Abstract

Background: guidelines for optimized use of digital follow-up of melanocytic lesions are not yet available, and little is known about inclusion criteria adopted in clinical practice. Objective. Our purpose was to describe the frequency of digital follow-up adoption in melanoma screening, the characteristics of patients and lesions selected, and the predictors of duration of the intervals of digital follow-up. Methods: Baseline characteristics of patients and lesions selected for digital follow-up in 12 Italian pigmented lesion clinics were examined. Predictors of a short follow-up interval (<= 3 months) compared with a 6-month interval were investigated by means of logistic regression analysis. Results: Out of 2116 subjects consecutively examined, 409 were submitted to digital follow-up (19.3%), with 1.6 mean lesions found per patient (range, 1-9; median, 1). According to an a posteriori analysis, 15.2% of the lesions were diagnostically equivocal and 7.8% of lesions had a total dermoscopy score (TDS) suggestive of malignancy. However, large differences in the TDS were found among the participating centers. Determinants of a short follow-up interval, adopted in 40.8% of patients, were the personal history of melanoma (odds ratio [OR] 2.56, 95% confidence interval [CI] 1.09-5.99) and the presence of atypical nevi (at least one atypical nevus (OR 4.54, 95% CI 2.45-8.42). Unexpectedly, the dermoscopic atypia of the lesion (TDS >4.75) was associated only with a marginal effect on the scheduled duration of follow-up interval (OR 1.34, 95% CI 0.97-1.86). These findings were confirmed by a multivariate analysis. Limitations. The adoption of different digital dermoscopy systems in the participating centers may have limited the reliability of the TDS assigned by a central group to dermoscopy images. Conclusions. Practicing dermatologists who use digital epiluminescence microscopy in screening for melanoma decided to submit at least one melanocytic lesion to digital follow-up for approximately I patient for every 5 examined. This implies costs and time spent that need to be evaluated together with the benefits of this procedure from a large-scale perspective. The lack of well-defined guidelines for inclusion and exclusion criteria may hamper optimized use of digital follow-up in daily practice.
2006
55
2
256
262
Baseline factors influencing decisions on digital follow-up of melanocytic lesions in daily practice: An Italian multicenter survey / P., Carli; G., Ghigliotti; M., Gnone; A., Chiarugi; E., Crocetti; S., Astorino; Ua, Berti; P., Broganelli; A., Carcaterra; Mt, Corradin; Pellacani, Giovanni; D., Piccolo; M., Risulo; I., Stanganelli; V., De Giorgi. - In: JOURNAL OF THE AMERICAN ACADEMY OF DERMATOLOGY. - ISSN 0190-9622. - STAMPA. - 55:2(2006), pp. 256-262. [10.1016/j.jaad.2005.12.026]
P., Carli; G., Ghigliotti; M., Gnone; A., Chiarugi; E., Crocetti; S., Astorino; Ua, Berti; P., Broganelli; A., Carcaterra; Mt, Corradin; Pellacani, Giovanni; D., Piccolo; M., Risulo; I., Stanganelli; V., De Giorgi
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

Licenza Creative Commons
I metadati presenti in IRIS UNIMORE sono rilasciati con licenza Creative Commons CC0 1.0 Universal, mentre i file delle pubblicazioni sono rilasciati con licenza Attribuzione 4.0 Internazionale (CC BY 4.0), salvo diversa indicazione.
In caso di violazione di copyright, contattare Supporto Iris

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11380/303664
Citazioni
  • ???jsp.display-item.citation.pmc??? 2
  • Scopus 11
  • ???jsp.display-item.citation.isi??? 11
social impact