A general purpose image processing system is described including B/W TV camera, high resolution image processor and display system (TESAK VDC 501), computer (DEC PDP 11/23), and monochrome and color monitors. Images may be acquired from a microscope equipped with a TV camera or using the TV in direct viewing; the A/D converter and the image processor provides fast (40 ms) and precise (512×512 data points) digitization of TV signal with a 256 gray levels maximum resolution. Computer programs have been developed in order to perform qualitative and quantitative analyses of autoradiographs obtained with the 2-DG method, which are written in FORTRAN and MACRO 11 Assembly Language. They include: (1) procedures designed to recognize errors in acquisition due to possible image shading and correct them via software; (2) routines suitable for qualitative analyses of the whole image or selected regions of it, providing the opportunity for pseudocolor coding, statistics, graphic overlays; (3) programs permitting the conversion of gray levels into metabolic rates of glucose utilization and the display of gray- or color-coded metabolic maps. © 1984.

Computer-assisted analyses of [14C]2-DG autoradiographs employing a general purpose image processing system / Porro, C.; Fonda, S.; Baraldi, P.; Biral, G. P.; Cavazzuti, M.. - In: JOURNAL OF NEUROSCIENCE METHODS. - ISSN 0165-0270. - 11:4(1984), pp. 243-250. [10.1016/0165-0270(84)90086-4]

Computer-assisted analyses of [14C]2-DG autoradiographs employing a general purpose image processing system

Porro C.;Fonda S.;Baraldi P.;Biral G. P.;
1984

Abstract

A general purpose image processing system is described including B/W TV camera, high resolution image processor and display system (TESAK VDC 501), computer (DEC PDP 11/23), and monochrome and color monitors. Images may be acquired from a microscope equipped with a TV camera or using the TV in direct viewing; the A/D converter and the image processor provides fast (40 ms) and precise (512×512 data points) digitization of TV signal with a 256 gray levels maximum resolution. Computer programs have been developed in order to perform qualitative and quantitative analyses of autoradiographs obtained with the 2-DG method, which are written in FORTRAN and MACRO 11 Assembly Language. They include: (1) procedures designed to recognize errors in acquisition due to possible image shading and correct them via software; (2) routines suitable for qualitative analyses of the whole image or selected regions of it, providing the opportunity for pseudocolor coding, statistics, graphic overlays; (3) programs permitting the conversion of gray levels into metabolic rates of glucose utilization and the display of gray- or color-coded metabolic maps. © 1984.
1984
11
4
243
250
Computer-assisted analyses of [14C]2-DG autoradiographs employing a general purpose image processing system / Porro, C.; Fonda, S.; Baraldi, P.; Biral, G. P.; Cavazzuti, M.. - In: JOURNAL OF NEUROSCIENCE METHODS. - ISSN 0165-0270. - 11:4(1984), pp. 243-250. [10.1016/0165-0270(84)90086-4]
Porro, C.; Fonda, S.; Baraldi, P.; Biral, G. P.; Cavazzuti, M.
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

Licenza Creative Commons
I metadati presenti in IRIS UNIMORE sono rilasciati con licenza Creative Commons CC0 1.0 Universal, mentre i file delle pubblicazioni sono rilasciati con licenza Attribuzione 4.0 Internazionale (CC BY 4.0), salvo diversa indicazione.
In caso di violazione di copyright, contattare Supporto Iris

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11380/1252199
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 21
  • ???jsp.display-item.citation.isi??? 20
social impact