This article deals with the stator cooling of an air-cooled, synchronous generator with a power rating of 400 kVA, which has been improved by adding two radial vents to the stator. To ensure an optimal vent design, a novel combined thermal and electromagnetic modelling approach is developed. A parametric 3D Conjugate Heat Transfer Computational Fluid Dynamics (CFD) model is used for the thermal modelling. An electromagnetic 2D Finite Element Analysis determined the impact that venting the stator has on the loss distribution. The models are coupled by deriving analytical correlations between the combined vent width and rotor copper, rotor iron and stator iron losses. These correlations are implemented into the optimisation procedure of the parametric CFD model. Five design parameters are optimised simultaneously with the aim of minimising the peak stator winding temperature. The modeling approach was validated experimentally by thermal, torque and mass flow measurements on the benchmark machine, as well as the newly designed prototype.

Thermal and Electromagnetic Stator Vent Design Optimisation for Synchronous Generators / Bersch, K.; Nuzzo, S.; Connor, P. H.; Eastwick, C. N.; Rolston, R.; Galea, M.. - In: IEEE TRANSACTIONS ON ENERGY CONVERSION. - ISSN 0885-8969. - 36:1(2021), pp. 207-217. [10.1109/TEC.2020.3004393]

Thermal and Electromagnetic Stator Vent Design Optimisation for Synchronous Generators

Nuzzo S.;
2021

Abstract

This article deals with the stator cooling of an air-cooled, synchronous generator with a power rating of 400 kVA, which has been improved by adding two radial vents to the stator. To ensure an optimal vent design, a novel combined thermal and electromagnetic modelling approach is developed. A parametric 3D Conjugate Heat Transfer Computational Fluid Dynamics (CFD) model is used for the thermal modelling. An electromagnetic 2D Finite Element Analysis determined the impact that venting the stator has on the loss distribution. The models are coupled by deriving analytical correlations between the combined vent width and rotor copper, rotor iron and stator iron losses. These correlations are implemented into the optimisation procedure of the parametric CFD model. Five design parameters are optimised simultaneously with the aim of minimising the peak stator winding temperature. The modeling approach was validated experimentally by thermal, torque and mass flow measurements on the benchmark machine, as well as the newly designed prototype.
2021
36
1
207
217
Thermal and Electromagnetic Stator Vent Design Optimisation for Synchronous Generators / Bersch, K.; Nuzzo, S.; Connor, P. H.; Eastwick, C. N.; Rolston, R.; Galea, M.. - In: IEEE TRANSACTIONS ON ENERGY CONVERSION. - ISSN 0885-8969. - 36:1(2021), pp. 207-217. [10.1109/TEC.2020.3004393]
Bersch, K.; Nuzzo, S.; Connor, P. H.; Eastwick, C. N.; Rolston, R.; Galea, M.
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

Licenza Creative Commons
I metadati presenti in IRIS UNIMORE sono rilasciati con licenza Creative Commons CC0 1.0 Universal, mentre i file delle pubblicazioni sono rilasciati con licenza Attribuzione 4.0 Internazionale (CC BY 4.0), salvo diversa indicazione.
In caso di violazione di copyright, contattare Supporto Iris

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11380/1237554
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 15
  • ???jsp.display-item.citation.isi??? 15
social impact