PURPOSE: VirtualTouch is a new technique recently proposed to evaluate liver stiffness during B-mode ultrasonography. The goal of the present study was to analyze the diagnostic accuracy of VirtualTouch in the diagnosis of cirrhosis and its correlation with transient elastography (Fibroscan). MATERIALS AND METHODS: A total of 133 patients with chronic liver disease were enrolled. 90 of 133 underwent VirtualTouch and transient elastography and 70 patients assessed with VirtualTouch were submitted to liver biopsy. Stiffness was assessed by both techniques in the right liver lobe. The diagnostic accuracy for cirrhosis was first assessed in the 90 patients submitted to transient elastography with > 13 kPa (47 % of patients) as diagnostic for cirrhosis values. The best cut-off for cirrhosis with VirtualTouch was then tested in the 70 patients with biopsy (cirrhosis in 38 % of patients). 41 patients were assessed by VirtualTouch by two different operators. RESULTS: The VirtualTouch values in controls, chronic hepatitis and cirrhosis were respectively 113, 147 and 255 cm/sec. The AUROC of liver VirtualTouch for the diagnosis of cirrhosis (reference Fibroscan) was 0.941 with 175 cm/sec as the best cut-off (sensitivity 93.0 %; specificity 85.1 %). VirtualTouch confirmed good performance also in patients with bioptic diagnosis of cirrhosis (AUROC 0.908, sensitivity 81.5 %, specificity 88.4 %,). The correlation of VirtualTouch with transient elastography was strict (r = 0.891) and the correlation in VirtualTouch measurements between two operators was also good (r = 0.874). CONCLUSION: VirtualTouch is able to identify the presence of cirrhosis with good accuracy, shows good interobserver reproducibility and the correlation of its values with those obtained by transient elastography with Fibroscan is good.

Accuracy of VirtualTouch Acoustic Radiation Force Impulse (ARFI) imaging for the diagnosis of cirrhosis during liver ultrasonography / Piscaglia, Fabio; Salvatore, Veronica; Di Donato, Roberto; D'Onofrio, M; Gualandi, Silvia; Gallotti, A; Peri, E; Borghi, Alberto; Conti, Fabio; Fattovich, G; Sagrini, Elisabetta; Cucchetti, Alessandro; Andreone, Pietro; Bolondi, Luigi. - In: ULTRASCHALL IN DER MEDIZIN. - ISSN 0172-4614. - 32:2(2011), pp. 167-175. [10.1055/s-0029-1245948]

Accuracy of VirtualTouch Acoustic Radiation Force Impulse (ARFI) imaging for the diagnosis of cirrhosis during liver ultrasonography

ANDREONE, PIETRO;
2011

Abstract

PURPOSE: VirtualTouch is a new technique recently proposed to evaluate liver stiffness during B-mode ultrasonography. The goal of the present study was to analyze the diagnostic accuracy of VirtualTouch in the diagnosis of cirrhosis and its correlation with transient elastography (Fibroscan). MATERIALS AND METHODS: A total of 133 patients with chronic liver disease were enrolled. 90 of 133 underwent VirtualTouch and transient elastography and 70 patients assessed with VirtualTouch were submitted to liver biopsy. Stiffness was assessed by both techniques in the right liver lobe. The diagnostic accuracy for cirrhosis was first assessed in the 90 patients submitted to transient elastography with > 13 kPa (47 % of patients) as diagnostic for cirrhosis values. The best cut-off for cirrhosis with VirtualTouch was then tested in the 70 patients with biopsy (cirrhosis in 38 % of patients). 41 patients were assessed by VirtualTouch by two different operators. RESULTS: The VirtualTouch values in controls, chronic hepatitis and cirrhosis were respectively 113, 147 and 255 cm/sec. The AUROC of liver VirtualTouch for the diagnosis of cirrhosis (reference Fibroscan) was 0.941 with 175 cm/sec as the best cut-off (sensitivity 93.0 %; specificity 85.1 %). VirtualTouch confirmed good performance also in patients with bioptic diagnosis of cirrhosis (AUROC 0.908, sensitivity 81.5 %, specificity 88.4 %,). The correlation of VirtualTouch with transient elastography was strict (r = 0.891) and the correlation in VirtualTouch measurements between two operators was also good (r = 0.874). CONCLUSION: VirtualTouch is able to identify the presence of cirrhosis with good accuracy, shows good interobserver reproducibility and the correlation of its values with those obtained by transient elastography with Fibroscan is good.
2011
32
2
167
175
Accuracy of VirtualTouch Acoustic Radiation Force Impulse (ARFI) imaging for the diagnosis of cirrhosis during liver ultrasonography / Piscaglia, Fabio; Salvatore, Veronica; Di Donato, Roberto; D'Onofrio, M; Gualandi, Silvia; Gallotti, A; Peri, E; Borghi, Alberto; Conti, Fabio; Fattovich, G; Sagrini, Elisabetta; Cucchetti, Alessandro; Andreone, Pietro; Bolondi, Luigi. - In: ULTRASCHALL IN DER MEDIZIN. - ISSN 0172-4614. - 32:2(2011), pp. 167-175. [10.1055/s-0029-1245948]
Piscaglia, Fabio; Salvatore, Veronica; Di Donato, Roberto; D'Onofrio, M; Gualandi, Silvia; Gallotti, A; Peri, E; Borghi, Alberto; Conti, Fabio; Fattovich, G; Sagrini, Elisabetta; Cucchetti, Alessandro; Andreone, Pietro; Bolondi, Luigi
File in questo prodotto:
File Dimensione Formato  
2011 ARFI Ultraschall.pdf

Accesso riservato

Dimensione 217.77 kB
Formato Adobe PDF
217.77 kB Adobe PDF   Visualizza/Apri   Richiedi una copia
Pubblicazioni consigliate

Licenza Creative Commons
I metadati presenti in IRIS UNIMORE sono rilasciati con licenza Creative Commons CC0 1.0 Universal, mentre i file delle pubblicazioni sono rilasciati con licenza Attribuzione 4.0 Internazionale (CC BY 4.0), salvo diversa indicazione.
In caso di violazione di copyright, contattare Supporto Iris

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11380/1237141
Citazioni
  • ???jsp.display-item.citation.pmc??? 26
  • Scopus 109
  • ???jsp.display-item.citation.isi??? 92
social impact