Background: Surgical resection of tumors invading the aorta is a challenging procedure. More recently, the use of thoracic aortic endografts has been reported to facilitate en bloc resection of tumors invading the aortic wall. The best treatment option is to keep the procedure separated before lung resection to reduce the risks of bleeding, therefore avoiding adverse consequences for the patient. However, an aortic stent placement before surgery is not mandatory with no clear signs of tumor or atherosclerotic plaque infiltrating the entire aortic wall. Case presentation: A 72-year-old man came to our Department for a persistent cough. Computed tomography (CT) scan with enhancement showed a mass located in the left upper lobe of the lung with no clear sign of infiltration or calcified plaques along the entire vascular wall. A positron emission tomography with 2-deoxy-2-[fluorine-18] fluoro-D-glucose integrated with computed tomography (PET/CT with 18F-FDG) was positive for hypermetabolic mass with negative lymph node stations bilaterally. Patient was undergone surgery for major lung resection by left thoracotomy. For an unexpected intraoperative bleeding due to the rupture of a calcified plaque, a stent was placed before proceeding with lung surgery. Patient was persistently stable, discharged after six days from surgery with no morbidities. Conclusions: In our case, no signs of the atherosclerotic plaque infiltration as well as no tumor infiltration were shown. In these situations, the aortic stent placement is possible in emergency, even during another operation. Nevertheless, surgeon experience and the good coordination among specialists is mandatory to yield a satisfying solution.

Intraoperative aortic endograft placement for an unexpected plaque rupture during lung surgery / Huang, W.; Aramini, B.; Fan, J.. - In: INTERNATIONAL JOURNAL OF SURGERY CASE REPORTS. - ISSN 2210-2612. - 60:(2019), pp. 161-163. [10.1016/j.ijscr.2019.06.001]

Intraoperative aortic endograft placement for an unexpected plaque rupture during lung surgery

Aramini B.;
2019

Abstract

Background: Surgical resection of tumors invading the aorta is a challenging procedure. More recently, the use of thoracic aortic endografts has been reported to facilitate en bloc resection of tumors invading the aortic wall. The best treatment option is to keep the procedure separated before lung resection to reduce the risks of bleeding, therefore avoiding adverse consequences for the patient. However, an aortic stent placement before surgery is not mandatory with no clear signs of tumor or atherosclerotic plaque infiltrating the entire aortic wall. Case presentation: A 72-year-old man came to our Department for a persistent cough. Computed tomography (CT) scan with enhancement showed a mass located in the left upper lobe of the lung with no clear sign of infiltration or calcified plaques along the entire vascular wall. A positron emission tomography with 2-deoxy-2-[fluorine-18] fluoro-D-glucose integrated with computed tomography (PET/CT with 18F-FDG) was positive for hypermetabolic mass with negative lymph node stations bilaterally. Patient was undergone surgery for major lung resection by left thoracotomy. For an unexpected intraoperative bleeding due to the rupture of a calcified plaque, a stent was placed before proceeding with lung surgery. Patient was persistently stable, discharged after six days from surgery with no morbidities. Conclusions: In our case, no signs of the atherosclerotic plaque infiltration as well as no tumor infiltration were shown. In these situations, the aortic stent placement is possible in emergency, even during another operation. Nevertheless, surgeon experience and the good coordination among specialists is mandatory to yield a satisfying solution.
2019
8-giu-2019
60
161
163
Intraoperative aortic endograft placement for an unexpected plaque rupture during lung surgery / Huang, W.; Aramini, B.; Fan, J.. - In: INTERNATIONAL JOURNAL OF SURGERY CASE REPORTS. - ISSN 2210-2612. - 60:(2019), pp. 161-163. [10.1016/j.ijscr.2019.06.001]
Huang, W.; Aramini, B.; Fan, J.
File in questo prodotto:
File Dimensione Formato  
1-s2.0-S2210261219303116-main.pdf

Open access

Tipologia: Versione pubblicata dall'editore
Dimensione 1.26 MB
Formato Adobe PDF
1.26 MB Adobe PDF Visualizza/Apri
Pubblicazioni consigliate

Licenza Creative Commons
I metadati presenti in IRIS UNIMORE sono rilasciati con licenza Creative Commons CC0 1.0 Universal, mentre i file delle pubblicazioni sono rilasciati con licenza Attribuzione 4.0 Internazionale (CC BY 4.0), salvo diversa indicazione.
In caso di violazione di copyright, contattare Supporto Iris

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11380/1204504
Citazioni
  • ???jsp.display-item.citation.pmc??? 0
  • Scopus 0
  • ???jsp.display-item.citation.isi??? 0
social impact