AimTo evaluate real-time PCR as a diagnostic method for Legionnaires' disease (LD). Detection of Legionella DNA is among the laboratory criteria of a probable LD case, according to the European Centre for Disease Prevention and Control, although the utility and advantages, as compared to culture, are widely recognised.MethodsTwo independent laboratories, one using an in-house and the other a commercial real-time PCR assay, analysed 354 respiratory samples from 311 patients hospitalised with pneumonia between 2010-15. The real-time PCR reliability was compared with that of culture and urinary antigen tests (UAT). Concordance, specificity, sensitivity and positive and negative predictive values (PPV and NPV, respectively) were calculated.ResultsOverall PCR detected eight additional LD cases, six of which were due to Legionella pneumophila (Lp) non-serogroup 1. The two real-time PCR assays were concordant in 99.4% of the samples. Considering in-house real-time PCR as the reference method, specificity of culture and UAT was 100% and 97.9% (95% CI: 96.2-99.6), while the sensitivity was 63.6% (95%CI: 58.6-68.6) and 77.8% (95% CI: 72.9-82.7). PPV and NPV for culture were 100% and 93.7% (95% CI: 91.2-96.3). PPV and NPV for UAT were 87.5% (95% CI: 83.6-91.4) and 95.8% (95% CI: 93.5-98.2).ConclusionRegardless of the real-time PCR assay used, it was possible to diagnose LD cases with higher sensitivity than using culture or UAT. These data encourage the adoption of PCR as routine laboratory testing to diagnose LD and such methods should be eligible to define a confirmed LD case.

Improvement of Legionnaires' disease diagnosis using real-time PCR assay: a retrospective analysis, Italy, 2010 to 2015 / Ricci, Maria Luisa; Grottola, Antonella; Fregni Serpini, Giulia; Bella, Antonino; Rota, Maria Cristina; Frascaro, Francesca; Pegoraro, Emanuela; Meacci, Marisa; Fabio, Anna; Vecchi, Elena; Girolamo, Antonietta; Rumpianesi, Fabio; Pecorari, Monica; Scaturro, Maria. - In: EUROSURVEILLANCE. - ISSN 1560-7917. - 23:50(2018), pp. 13-17. [10.2807/1560-7917.ES.2018.23.50.1800032]

Improvement of Legionnaires' disease diagnosis using real-time PCR assay: a retrospective analysis, Italy, 2010 to 2015

Grottola, Antonella;
2018

Abstract

AimTo evaluate real-time PCR as a diagnostic method for Legionnaires' disease (LD). Detection of Legionella DNA is among the laboratory criteria of a probable LD case, according to the European Centre for Disease Prevention and Control, although the utility and advantages, as compared to culture, are widely recognised.MethodsTwo independent laboratories, one using an in-house and the other a commercial real-time PCR assay, analysed 354 respiratory samples from 311 patients hospitalised with pneumonia between 2010-15. The real-time PCR reliability was compared with that of culture and urinary antigen tests (UAT). Concordance, specificity, sensitivity and positive and negative predictive values (PPV and NPV, respectively) were calculated.ResultsOverall PCR detected eight additional LD cases, six of which were due to Legionella pneumophila (Lp) non-serogroup 1. The two real-time PCR assays were concordant in 99.4% of the samples. Considering in-house real-time PCR as the reference method, specificity of culture and UAT was 100% and 97.9% (95% CI: 96.2-99.6), while the sensitivity was 63.6% (95%CI: 58.6-68.6) and 77.8% (95% CI: 72.9-82.7). PPV and NPV for culture were 100% and 93.7% (95% CI: 91.2-96.3). PPV and NPV for UAT were 87.5% (95% CI: 83.6-91.4) and 95.8% (95% CI: 93.5-98.2).ConclusionRegardless of the real-time PCR assay used, it was possible to diagnose LD cases with higher sensitivity than using culture or UAT. These data encourage the adoption of PCR as routine laboratory testing to diagnose LD and such methods should be eligible to define a confirmed LD case.
2018
dic-2018
23
50
13
17
Improvement of Legionnaires' disease diagnosis using real-time PCR assay: a retrospective analysis, Italy, 2010 to 2015 / Ricci, Maria Luisa; Grottola, Antonella; Fregni Serpini, Giulia; Bella, Antonino; Rota, Maria Cristina; Frascaro, Francesca; Pegoraro, Emanuela; Meacci, Marisa; Fabio, Anna; Vecchi, Elena; Girolamo, Antonietta; Rumpianesi, Fabio; Pecorari, Monica; Scaturro, Maria. - In: EUROSURVEILLANCE. - ISSN 1560-7917. - 23:50(2018), pp. 13-17. [10.2807/1560-7917.ES.2018.23.50.1800032]
Ricci, Maria Luisa; Grottola, Antonella; Fregni Serpini, Giulia; Bella, Antonino; Rota, Maria Cristina; Frascaro, Francesca; Pegoraro, Emanuela; Meacci, Marisa; Fabio, Anna; Vecchi, Elena; Girolamo, Antonietta; Rumpianesi, Fabio; Pecorari, Monica; Scaturro, Maria
File in questo prodotto:
File Dimensione Formato  
eurosurv-23-50-3.pdf

Open access

Tipologia: Versione pubblicata dall'editore
Dimensione 115.44 kB
Formato Adobe PDF
115.44 kB Adobe PDF Visualizza/Apri
Pubblicazioni consigliate

Licenza Creative Commons
I metadati presenti in IRIS UNIMORE sono rilasciati con licenza Creative Commons CC0 1.0 Universal, mentre i file delle pubblicazioni sono rilasciati con licenza Attribuzione 4.0 Internazionale (CC BY 4.0), salvo diversa indicazione.
In caso di violazione di copyright, contattare Supporto Iris

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11380/1176339
Citazioni
  • ???jsp.display-item.citation.pmc??? 7
  • Scopus 10
  • ???jsp.display-item.citation.isi??? 7
social impact