Purpose: For assessing healthy liver reactions after robotic SBRT (stereotactic body radiotherapy), we investigated early morphologic alterations on MRI (magnetic resonance imaging) with respect to patient and treatment plan parameters. Patients and methods: MRI data at 6–17 weeks post-treatment from 22 patients with 42 liver metastases were analyzed retrospectively. Median prescription dose was 40 Gy delivered in 3–5 fractions. T2- and T1-weighted MRI were registered to the treatment plan. Absolute doses were converted to EQD2 (Equivalent dose in 2Gy fractions) with α/β-ratios of 2 and 3 Gy for healthy, and 8 Gy for modelling pre-damaged liver tissue. Results: Sharply defined, centroid-shaped morphologic alterations were observed outside the high-dose volume surrounding the GTV. On T2-w MRI, hyperintensity at EQD2 isodoses of 113.3 ± 66.1 Gy2, 97.5 ± 54.7 Gy3, and 66.5 ± 32.0 Gy8 significantly depended on PTV dimension (p = 0.02) and healthy liver EQD2 (p = 0.05). On T1-w non-contrast MRI, hypointensity at EQD2 isodoses of 113.3 ± 49.3 Gy2, 97.4 ± 41.0 Gy3, and 65.7 ± 24.2 Gy8 significantly depended on prior chemotherapy (p = 0.01) and total liver volume (p = 0.05). On T1-w gadolinium-contrast delayed MRI, hypointensity at EQD2 isodoses of 90.6 ± 42.5 Gy2, 79.3 ± 35.3 Gy3, and 56.6 ± 20.9 Gy8 significantly depended on total (p = 0.04) and healthy (p = 0.01) liver EQD2. Conclusions: Early post-treatment changes in healthy liver tissue after robotic SBRT could spatially be correlated to respective isodoses. Median nominal doses of 10.1–11.3 Gy per fraction (EQD2 79–97 Gy3) induce characteristic morphologic alterations surrounding the lesions, potentially allowing for dosimetric in-vivo accuracy assessments. Comparison to other techniques and investigations of the short- and long-term clinical impact require further research.

Direct dose correlation of MRI morphologic alterations of healthy liver tissue after robotic liver SBRT / Boda-Heggemann, Judit; Jahnke, Anika; Chan, Mark K. H.; Ghaderi Ardekani, Leila S.; Hunold, Peter; Schäfer, Jost Philipp; Huttenlocher, Stefan; Wurster, Stefan; Rades, Dirk; Hildebrandt, Guido; Lohr, Frank; Dunst, Jürgen; Wenz, Frederik; Blanck, Oliver. - In: STRAHLENTHERAPIE UND ONKOLOGIE. - ISSN 0179-7158. - 194:5(2018), pp. 414-424. [10.1007/s00066-018-1271-9]

Direct dose correlation of MRI morphologic alterations of healthy liver tissue after robotic liver SBRT

Lohr, Frank;
2018

Abstract

Purpose: For assessing healthy liver reactions after robotic SBRT (stereotactic body radiotherapy), we investigated early morphologic alterations on MRI (magnetic resonance imaging) with respect to patient and treatment plan parameters. Patients and methods: MRI data at 6–17 weeks post-treatment from 22 patients with 42 liver metastases were analyzed retrospectively. Median prescription dose was 40 Gy delivered in 3–5 fractions. T2- and T1-weighted MRI were registered to the treatment plan. Absolute doses were converted to EQD2 (Equivalent dose in 2Gy fractions) with α/β-ratios of 2 and 3 Gy for healthy, and 8 Gy for modelling pre-damaged liver tissue. Results: Sharply defined, centroid-shaped morphologic alterations were observed outside the high-dose volume surrounding the GTV. On T2-w MRI, hyperintensity at EQD2 isodoses of 113.3 ± 66.1 Gy2, 97.5 ± 54.7 Gy3, and 66.5 ± 32.0 Gy8 significantly depended on PTV dimension (p = 0.02) and healthy liver EQD2 (p = 0.05). On T1-w non-contrast MRI, hypointensity at EQD2 isodoses of 113.3 ± 49.3 Gy2, 97.4 ± 41.0 Gy3, and 65.7 ± 24.2 Gy8 significantly depended on prior chemotherapy (p = 0.01) and total liver volume (p = 0.05). On T1-w gadolinium-contrast delayed MRI, hypointensity at EQD2 isodoses of 90.6 ± 42.5 Gy2, 79.3 ± 35.3 Gy3, and 56.6 ± 20.9 Gy8 significantly depended on total (p = 0.04) and healthy (p = 0.01) liver EQD2. Conclusions: Early post-treatment changes in healthy liver tissue after robotic SBRT could spatially be correlated to respective isodoses. Median nominal doses of 10.1–11.3 Gy per fraction (EQD2 79–97 Gy3) induce characteristic morphologic alterations surrounding the lesions, potentially allowing for dosimetric in-vivo accuracy assessments. Comparison to other techniques and investigations of the short- and long-term clinical impact require further research.
2018
5-feb-2018
194
5
414
424
Direct dose correlation of MRI morphologic alterations of healthy liver tissue after robotic liver SBRT / Boda-Heggemann, Judit; Jahnke, Anika; Chan, Mark K. H.; Ghaderi Ardekani, Leila S.; Hunold, Peter; Schäfer, Jost Philipp; Huttenlocher, Stefan; Wurster, Stefan; Rades, Dirk; Hildebrandt, Guido; Lohr, Frank; Dunst, Jürgen; Wenz, Frederik; Blanck, Oliver. - In: STRAHLENTHERAPIE UND ONKOLOGIE. - ISSN 0179-7158. - 194:5(2018), pp. 414-424. [10.1007/s00066-018-1271-9]
Boda-Heggemann, Judit; Jahnke, Anika; Chan, Mark K. H.; Ghaderi Ardekani, Leila S.; Hunold, Peter; Schäfer, Jost Philipp; Huttenlocher, Stefan; Wurster, Stefan; Rades, Dirk; Hildebrandt, Guido; Lohr, Frank; Dunst, Jürgen; Wenz, Frederik; Blanck, Oliver
File in questo prodotto:
File Dimensione Formato  
boda-heggemann2018.pdf

Accesso riservato

Tipologia: Versione pubblicata dall'editore
Dimensione 1.21 MB
Formato Adobe PDF
1.21 MB Adobe PDF   Visualizza/Apri   Richiedi una copia
Pubblicazioni consigliate

Licenza Creative Commons
I metadati presenti in IRIS UNIMORE sono rilasciati con licenza Creative Commons CC0 1.0 Universal, mentre i file delle pubblicazioni sono rilasciati con licenza Attribuzione 4.0 Internazionale (CC BY 4.0), salvo diversa indicazione.
In caso di violazione di copyright, contattare Supporto Iris

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11380/1172299
Citazioni
  • ???jsp.display-item.citation.pmc??? 6
  • Scopus 18
  • ???jsp.display-item.citation.isi??? 18
social impact