Baseline wander removal is an unavoidable preprocessing step in ECG signal analysis. Unfortunately, the in-band nature of this kind of noise makes its removal difficult without affecting ECG waveform, in particular the ST segment. This is a portion of the ECG with high clinical relevance, as it is related to the diagnosis of acute coronary syndromes. The ST segment is highly susceptible to distortion when baseline removal is performed affecting the low-frequency region of ECG spectrum, where are concentrated the harmonic components that mainly contribute to the shape of the ST segment. In this paper, we propose to tackle the problem of baseline removal from a different perspective, considering the quadratic variation as an alternative measure of variability not directly related to the frequency domain. In this regard, we recently proposed a novel baseline removal algorithm based on quadratic variation reduction. In this paper, we assess its performance with respect to the distortion of the ST segment comparing it to state-of-the-art algorithms. Simulation results confirm the effectiveness of the approach based on quadratic variation reduction. Our algorithm outperforms state-of-the-art algorithms tailored to minimize distortion of the ST segment. Moreover, it compares favorably also in terms of computational complexity, which is linear in the size of the vector to detrend. This makes it suitable also for real-time applications. © 2011 ACM.

Fast ECG baseline wander removal preserving the ST segment / Fasano, Antonio; Villani, Valeria; Vollero, Luca. - (2011), pp. 1-5. (Intervento presentato al convegno 4th International Symposium on Applied Sciences in Biomedical and Communication Technologies, ISABEL'11 tenutosi a Barcelona, esp nel 2011) [10.1145/2093698.2093754].

Fast ECG baseline wander removal preserving the ST segment

VILLANI, VALERIA;
2011

Abstract

Baseline wander removal is an unavoidable preprocessing step in ECG signal analysis. Unfortunately, the in-band nature of this kind of noise makes its removal difficult without affecting ECG waveform, in particular the ST segment. This is a portion of the ECG with high clinical relevance, as it is related to the diagnosis of acute coronary syndromes. The ST segment is highly susceptible to distortion when baseline removal is performed affecting the low-frequency region of ECG spectrum, where are concentrated the harmonic components that mainly contribute to the shape of the ST segment. In this paper, we propose to tackle the problem of baseline removal from a different perspective, considering the quadratic variation as an alternative measure of variability not directly related to the frequency domain. In this regard, we recently proposed a novel baseline removal algorithm based on quadratic variation reduction. In this paper, we assess its performance with respect to the distortion of the ST segment comparing it to state-of-the-art algorithms. Simulation results confirm the effectiveness of the approach based on quadratic variation reduction. Our algorithm outperforms state-of-the-art algorithms tailored to minimize distortion of the ST segment. Moreover, it compares favorably also in terms of computational complexity, which is linear in the size of the vector to detrend. This makes it suitable also for real-time applications. © 2011 ACM.
2011
4th International Symposium on Applied Sciences in Biomedical and Communication Technologies, ISABEL'11
Barcelona, esp
2011
1
5
Fasano, Antonio; Villani, Valeria; Vollero, Luca
Fast ECG baseline wander removal preserving the ST segment / Fasano, Antonio; Villani, Valeria; Vollero, Luca. - (2011), pp. 1-5. (Intervento presentato al convegno 4th International Symposium on Applied Sciences in Biomedical and Communication Technologies, ISABEL'11 tenutosi a Barcelona, esp nel 2011) [10.1145/2093698.2093754].
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

Licenza Creative Commons
I metadati presenti in IRIS UNIMORE sono rilasciati con licenza Creative Commons CC0 1.0 Universal, mentre i file delle pubblicazioni sono rilasciati con licenza Attribuzione 4.0 Internazionale (CC BY 4.0), salvo diversa indicazione.
In caso di violazione di copyright, contattare Supporto Iris

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11380/1141744
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 8
  • ???jsp.display-item.citation.isi??? ND
social impact