Baseline wander is a kind of noise that affects all ECG signals. We have recently proposed a novel approach to its removal which is based on Quadratic Variation Reduction (QVR). The approach has very favorable properties and has shown to be effective in removing baseline wander, while preserving the ST segment level. It requires the determination of a detrending parameter. In this pa- per, we derive a linear time-invariant filter approximating QVR. The filter retains (approximately) the same optimality properties as QVR. Moreover, it provides a criterion for choosing the proper value of the parameter governing QVR, as a function of the spectral characteristics of base- line wander noise. Simulation results show that the filter is effective in removing baseline wander, while introducing minor distortion in the ST segment.

Baseline Wander Removal in ECG and AHA Recommendations / Fasano, Antonio; Villani, Valeria. - In: COMPUTING IN CARDIOLOGY. - ISSN 2325-8861. - 40:(2013), pp. 1171-1174. (Intervento presentato al convegno 2013 40th Computing in Cardiology Conference, CinC 2013 tenutosi a Zaragoza (ES) nel Sep. 23-25, 2013).

Baseline Wander Removal in ECG and AHA Recommendations

Villani, Valeria
2013

Abstract

Baseline wander is a kind of noise that affects all ECG signals. We have recently proposed a novel approach to its removal which is based on Quadratic Variation Reduction (QVR). The approach has very favorable properties and has shown to be effective in removing baseline wander, while preserving the ST segment level. It requires the determination of a detrending parameter. In this pa- per, we derive a linear time-invariant filter approximating QVR. The filter retains (approximately) the same optimality properties as QVR. Moreover, it provides a criterion for choosing the proper value of the parameter governing QVR, as a function of the spectral characteristics of base- line wander noise. Simulation results show that the filter is effective in removing baseline wander, while introducing minor distortion in the ST segment.
2013
2013 40th Computing in Cardiology Conference, CinC 2013
Zaragoza (ES)
Sep. 23-25, 2013
40
1171
1174
Fasano, Antonio; Villani, Valeria
Baseline Wander Removal in ECG and AHA Recommendations / Fasano, Antonio; Villani, Valeria. - In: COMPUTING IN CARDIOLOGY. - ISSN 2325-8861. - 40:(2013), pp. 1171-1174. (Intervento presentato al convegno 2013 40th Computing in Cardiology Conference, CinC 2013 tenutosi a Zaragoza (ES) nel Sep. 23-25, 2013).
File in questo prodotto:
File Dimensione Formato  
Baseline Wander Removal in ECG and AHA Recommendations.pdf

Accesso riservato

Tipologia: Versione pubblicata dall'editore
Dimensione 694.08 kB
Formato Adobe PDF
694.08 kB Adobe PDF   Visualizza/Apri   Richiedi una copia
Pubblicazioni consigliate

Licenza Creative Commons
I metadati presenti in IRIS UNIMORE sono rilasciati con licenza Creative Commons CC0 1.0 Universal, mentre i file delle pubblicazioni sono rilasciati con licenza Attribuzione 4.0 Internazionale (CC BY 4.0), salvo diversa indicazione.