Use of cardiac implantable devices and catheter ablation is steadily increasing in Western countries following the positive results of clinical trials. Despite the advances in scientific knowledge, tools development, and techniques improvement we still have some grey area in the field of electrical therapies for the heart. In particular, several reports highlighted differences both in medical behaviour and procedural outcomes between female and male candidates. Women are referred later for catheter ablation of supraventricular arrhythmias, especially atrial fibrillation, leading to suboptimal results. On the opposite females present greater response to cardiac resynchronization, while the benefit of implantable defibrillator in primary prevention seems to be less pronounced. Differences on aetiology, clinical profile, and development of myocardial scarring are the more plausible causes. This review will discuss all these aspects together with gender-related differences in terms of acute/late complications. We will also provide useful hints on plausible mechanisms and practical procedural aspects.

The effects of gender on electrical therapies for the heart: procedural considerations, results and complications: A report from the XII Congress of the Italian Association on Arrhythmology and Cardiostimulation (AIAC) / Diemberger, Igor; Marazzi, Raffaella; Casella, Michela; Vassanelli, Francesca; Galimberti, Paola; Luzi, Mario; Borrelli, Alessio; Soldati, Ezio; Golzio, Pier Giorgio; Fumagalli, Stefano; Francia, Pietro; Padeletti, Luigi; Botto, Gianluca; Boriani, Giuseppe. - In: EUROPACE. - ISSN 1099-5129. - 19:12(2017), pp. 1911-1921. [10.1093/europace/eux034]

The effects of gender on electrical therapies for the heart: procedural considerations, results and complications: A report from the XII Congress of the Italian Association on Arrhythmology and Cardiostimulation (AIAC)

BORIANI, Giuseppe
2017

Abstract

Use of cardiac implantable devices and catheter ablation is steadily increasing in Western countries following the positive results of clinical trials. Despite the advances in scientific knowledge, tools development, and techniques improvement we still have some grey area in the field of electrical therapies for the heart. In particular, several reports highlighted differences both in medical behaviour and procedural outcomes between female and male candidates. Women are referred later for catheter ablation of supraventricular arrhythmias, especially atrial fibrillation, leading to suboptimal results. On the opposite females present greater response to cardiac resynchronization, while the benefit of implantable defibrillator in primary prevention seems to be less pronounced. Differences on aetiology, clinical profile, and development of myocardial scarring are the more plausible causes. This review will discuss all these aspects together with gender-related differences in terms of acute/late complications. We will also provide useful hints on plausible mechanisms and practical procedural aspects.
2017
19
12
1911
1921
The effects of gender on electrical therapies for the heart: procedural considerations, results and complications: A report from the XII Congress of the Italian Association on Arrhythmology and Cardiostimulation (AIAC) / Diemberger, Igor; Marazzi, Raffaella; Casella, Michela; Vassanelli, Francesca; Galimberti, Paola; Luzi, Mario; Borrelli, Alessio; Soldati, Ezio; Golzio, Pier Giorgio; Fumagalli, Stefano; Francia, Pietro; Padeletti, Luigi; Botto, Gianluca; Boriani, Giuseppe. - In: EUROPACE. - ISSN 1099-5129. - 19:12(2017), pp. 1911-1921. [10.1093/europace/eux034]
Diemberger, Igor; Marazzi, Raffaella; Casella, Michela; Vassanelli, Francesca; Galimberti, Paola; Luzi, Mario; Borrelli, Alessio; Soldati, Ezio; Golzio, Pier Giorgio; Fumagalli, Stefano; Francia, Pietro; Padeletti, Luigi; Botto, Gianluca; Boriani, Giuseppe
File in questo prodotto:
File Dimensione Formato  
eux034.pdf

Open access

Tipologia: Versione pubblicata dall'editore
Dimensione 378.44 kB
Formato Adobe PDF
378.44 kB Adobe PDF Visualizza/Apri
Pubblicazioni consigliate

Licenza Creative Commons
I metadati presenti in IRIS UNIMORE sono rilasciati con licenza Creative Commons CC0 1.0 Universal, mentre i file delle pubblicazioni sono rilasciati con licenza Attribuzione 4.0 Internazionale (CC BY 4.0), salvo diversa indicazione.
In caso di violazione di copyright, contattare Supporto Iris

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11380/1139435
Citazioni
  • ???jsp.display-item.citation.pmc??? 1
  • Scopus 3
  • ???jsp.display-item.citation.isi??? 3
social impact