Background: A plethora of clinical studies have assessed the benefits of implantable cardioverter defibrillators (ICDs) and supported their use in clinical practice. However, evidence on the safety and efficacy of ICDs appears insufficient to support expansion of their use in clinical practice, and more information on their impact in real life settings is warranted. This paper aims to investigate the impact of ICDs using a large administrative dataset reflecting actual clinical practice. Methods: Data were obtained from the hospital discharge database of the Friuli Venezia Giulia region in Italy containing patient-level information on 169,488 cases. Data on mortality outside hospital were obtained from regional sources. Exact matching method was used to estimate the outcomes associated with ICDs: mortality, length of stay, re-hospitalization and regional expenditure. The method was applied in two steps. First, patients with ICDs were matched with those without using the following: age class (by 5 years), gender, year of admission, type of admission (day hospital vs. ordinary) and primary diagnosis. In the second step, matching included also Charlson Comorbidities Index. Exact matching average treatment effect on the treated (ATT) was used as a main measure of impact. Results: Compared with matched controls, treatment with ICDs was associated with lower mortality (absolute risk reduction 10.6% at 1 year and 8.3% at 2 and 8.4% at 3 years, p < 0.001 and hazard ratio 0.80, p < 0.001), greater regional expenditure at index hospitalization (ATT: (sic)9459.64, p < 0.001) and during follow up (ATT: (sic)1707.29, p < 0.001) and higher re-hospitalization rate (ATT: 0.53, p < 0.001). No significant difference was found for length of stay (9.07 vs. 8.86 days). The results were maintained after more restrictive matching was applied. Conclusions: Assessing the impact of innovative, expensive medical technologies on the basis of real world data is warranted, especially when there are barriers to implementation. Hospital administrative datasets can be of great value when a technology such as the ICD is implemented in a relatively small sample of patients, to allow use of exact matching techniques.

Assessing the outcomes of implantable cardioverter defibrillator treatment in a real world setting: results from hospital record data / S., Ghislandi; A., Torbica; Boriani, Giuseppe. - In: BMC HEALTH SERVICES RESEARCH. - ISSN 1472-6963. - 13:100(2013), pp. 1-13. [10.1186/1472-6963-13-100]

Assessing the outcomes of implantable cardioverter defibrillator treatment in a real world setting: results from hospital record data

BORIANI, Giuseppe
2013

Abstract

Background: A plethora of clinical studies have assessed the benefits of implantable cardioverter defibrillators (ICDs) and supported their use in clinical practice. However, evidence on the safety and efficacy of ICDs appears insufficient to support expansion of their use in clinical practice, and more information on their impact in real life settings is warranted. This paper aims to investigate the impact of ICDs using a large administrative dataset reflecting actual clinical practice. Methods: Data were obtained from the hospital discharge database of the Friuli Venezia Giulia region in Italy containing patient-level information on 169,488 cases. Data on mortality outside hospital were obtained from regional sources. Exact matching method was used to estimate the outcomes associated with ICDs: mortality, length of stay, re-hospitalization and regional expenditure. The method was applied in two steps. First, patients with ICDs were matched with those without using the following: age class (by 5 years), gender, year of admission, type of admission (day hospital vs. ordinary) and primary diagnosis. In the second step, matching included also Charlson Comorbidities Index. Exact matching average treatment effect on the treated (ATT) was used as a main measure of impact. Results: Compared with matched controls, treatment with ICDs was associated with lower mortality (absolute risk reduction 10.6% at 1 year and 8.3% at 2 and 8.4% at 3 years, p < 0.001 and hazard ratio 0.80, p < 0.001), greater regional expenditure at index hospitalization (ATT: (sic)9459.64, p < 0.001) and during follow up (ATT: (sic)1707.29, p < 0.001) and higher re-hospitalization rate (ATT: 0.53, p < 0.001). No significant difference was found for length of stay (9.07 vs. 8.86 days). The results were maintained after more restrictive matching was applied. Conclusions: Assessing the impact of innovative, expensive medical technologies on the basis of real world data is warranted, especially when there are barriers to implementation. Hospital administrative datasets can be of great value when a technology such as the ICD is implemented in a relatively small sample of patients, to allow use of exact matching techniques.
2013
13
100
1
13
Assessing the outcomes of implantable cardioverter defibrillator treatment in a real world setting: results from hospital record data / S., Ghislandi; A., Torbica; Boriani, Giuseppe. - In: BMC HEALTH SERVICES RESEARCH. - ISSN 1472-6963. - 13:100(2013), pp. 1-13. [10.1186/1472-6963-13-100]
S., Ghislandi; A., Torbica; Boriani, Giuseppe
File in questo prodotto:
File Dimensione Formato  
1472-6963-13-100.pdf

Open access

Tipologia: Versione pubblicata dall'editore
Dimensione 301.71 kB
Formato Adobe PDF
301.71 kB Adobe PDF Visualizza/Apri
Pubblicazioni consigliate

Licenza Creative Commons
I metadati presenti in IRIS UNIMORE sono rilasciati con licenza Creative Commons CC0 1.0 Universal, mentre i file delle pubblicazioni sono rilasciati con licenza Attribuzione 4.0 Internazionale (CC BY 4.0), salvo diversa indicazione.
In caso di violazione di copyright, contattare Supporto Iris

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11380/1080447
Citazioni
  • ???jsp.display-item.citation.pmc??? 1
  • Scopus 6
  • ???jsp.display-item.citation.isi??? 4
social impact