Background. A 64-year-old woman was referred to our center because of poorly tolerated ventricular tachycardia (VT) at 210 bpm due to an old myocardial infarction. The patient had been operated on at age of 20 for mitral valve commissurolysis, at age of 49 for ductal carcinoma, at age of 56 for mitral valve replacement, and at age of 61 for tricuspid valve replacement. Left ventricular EF was 31%. The patient was in permanent atrial fibrillation (AF) since the age of 53. She had undergone three cardiac surgery procedures, ending with two prosthetic mechanical valves. The cardiac surgery team advised against an epicardial ICD implantation. Results. We achieved a fully transvenous implant, with a screw-in defibrillation coil in the low right atrium and a bipolar pacing/sensing lead in a posterolateral branch of the coronary sinus. Pacing/sensing parameters were reliable, and effective defibrillation occurred at 20 J by a stepdown protocol. During 16-month follow-up, three VT episodes at 210 bpm were terminated by antitachycardia pacing (ATP) therapy. Left ventricular pacing/sensing was stable at long term. Conclusion. Thanks to technologic improvements, transvenous ICD implantation is feasible and safe in patients with a tricuspid mechanical prosthesis

Transvenous cardioverter-defibrillator implantation in a patient with tricuspid mechanical prosthesis / Biffi, M; Bertini, M; Ziacchi, M; Boriani, Giuseppe. - In: JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY. - ISSN 1045-3873. - 18:3(2007), pp. 329-331. [10.1111/j.1540-8167.2006.00686.x]

Transvenous cardioverter-defibrillator implantation in a patient with tricuspid mechanical prosthesis.

BORIANI, Giuseppe
2007

Abstract

Background. A 64-year-old woman was referred to our center because of poorly tolerated ventricular tachycardia (VT) at 210 bpm due to an old myocardial infarction. The patient had been operated on at age of 20 for mitral valve commissurolysis, at age of 49 for ductal carcinoma, at age of 56 for mitral valve replacement, and at age of 61 for tricuspid valve replacement. Left ventricular EF was 31%. The patient was in permanent atrial fibrillation (AF) since the age of 53. She had undergone three cardiac surgery procedures, ending with two prosthetic mechanical valves. The cardiac surgery team advised against an epicardial ICD implantation. Results. We achieved a fully transvenous implant, with a screw-in defibrillation coil in the low right atrium and a bipolar pacing/sensing lead in a posterolateral branch of the coronary sinus. Pacing/sensing parameters were reliable, and effective defibrillation occurred at 20 J by a stepdown protocol. During 16-month follow-up, three VT episodes at 210 bpm were terminated by antitachycardia pacing (ATP) therapy. Left ventricular pacing/sensing was stable at long term. Conclusion. Thanks to technologic improvements, transvenous ICD implantation is feasible and safe in patients with a tricuspid mechanical prosthesis
2007
18
3
329
331
Transvenous cardioverter-defibrillator implantation in a patient with tricuspid mechanical prosthesis / Biffi, M; Bertini, M; Ziacchi, M; Boriani, Giuseppe. - In: JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY. - ISSN 1045-3873. - 18:3(2007), pp. 329-331. [10.1111/j.1540-8167.2006.00686.x]
Biffi, M; Bertini, M; Ziacchi, M; Boriani, Giuseppe
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

Licenza Creative Commons
I metadati presenti in IRIS UNIMORE sono rilasciati con licenza Creative Commons CC0 1.0 Universal, mentre i file delle pubblicazioni sono rilasciati con licenza Attribuzione 4.0 Internazionale (CC BY 4.0), salvo diversa indicazione.
In caso di violazione di copyright, contattare Supporto Iris

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11380/1080321
Citazioni
  • ???jsp.display-item.citation.pmc??? 4
  • Scopus 8
  • ???jsp.display-item.citation.isi??? 7
social impact